CUT55 NON-HF Specifications
Technical Parameters
→ Swipe to view all columns
| Items | CUT55 NON-HF AC220V 50/60Hz |
CUT55 NON-HF AC110V 50/60Hz |
|---|---|---|
| Rated Input Capacity (kVA) | 9.2 | 5.5 |
| Power Factor | 0.7 | 0.7 |
| Rated Output (A/V) | 55 / 100 | 35 / 94 |
| Rated Duty Cycle (%) | 60 | 60 |
| No-load Voltage (V) | 310 | 310 |
| Output Current Range (A) | 20 – 55 | 20 – 35 |
| Arc Ignition Mode | NON-HF Non-Contact | NON-HF Non-Contact |
| Post-flow Time (s) | 5 | 5 |
| Gas Pressure Range | 0.21 – 0.49 MPa / 30.5 – 71.0 PSI | 0.21 – 0.49 MPa / 30.5 – 71.0 PSI |
| Insulation Grade | H | H |
| Cooling Mode | Air Cooling | Air Cooling |
| Enclosure Ingress Protection | IP21S | IP21S |
| Efficiency (%) | 85 | 85 |
| Maximum Cutting Thickness | 1" | 9/16" |
| Ideal Clean Cut Thickness | 11/16" | 1/2" |